{"title":"Compensation components","description":"\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n \u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003ePelek.eu offers a wide range of components for reactive power compensation, which are essential for optimizing the energy efficiency of your industrial applications. Products from TENSE and other Turkish manufacturers with whom we cooperate are distinguished by their quality and reliability. In our offer you will find compensation capacitors, reactors, regulators and other specialized components that will help reduce energy costs and extend the service life of your equipment. With our products you will get a comprehensive solution that is available at competitive prices and comes with fast service and technical support.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"rgt-mt18-18-lygiu-reaktyviosios-galios-valdiklis-tcr-su-rs485-modbus","title":"RGT-MT18 - 18-level reactive power controller +TCR with RS485 ModBus","description":"\u003cp\u003e\u003cstrong\u003e18-step + TCR Power Factor Controller for Symmetrical\/Asymmetrical Networks with 5-inch Touch Screen and RS-485 (TENSE)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eReactive power regulation relays are used to reduce the reactive power (inductive and capacitive) that is not consumed by the load and is drawn from the network. When inductive power is drawn from the network, it intervenes by switching in a capacitor of appropriate value. If capacitive power is drawn from the network, it intervenes by switching in a shunt inductor of appropriate value. This aims to reduce the inductive\/active and capacitive\/active ratios of the system. It is designed to provide more acceptable compensation in unbalanced inductive and capacitive systems with an RGT-MT18 TCR step.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003eGenerator input and generator compensation\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eVoltage, harmonic current\/voltage, inductive and capacitive alarm output\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eTurn-on, discharge, and settling times can be adjusted\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eRemote communication via RS485 (RS485 ModBus RTU)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eSingle-phase, two-phase, and three-phase capacitor and shunt reactor connection possible\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eHarmonic voltage and current up to the 61st harmonic can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eTotal energy (import and export) can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eTHD-V and THD-I values for each phase can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003ePower analysis created (20 samples for 9999 min) - for capacitor selection\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eTemperature alarm output\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eDemand recording (active and reactive and apparent power and current demand)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eMinimum, maximum, and average current and voltage values for each phase can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eActual date and time\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":55794558402895,"sku":"RGT-MT18","price":334.08,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/4589\/0127\/files\/29021cc84c53911daf6559abe27a8950.png?v=1756156241"},{"product_id":"rgt-12e-12-lygiu-reaktyviosios-galios-reguliatorius-tcr","title":"RGT-12E - 12-level reactive power regulator +TCR","description":"\u003ch1 data-start=\"175\" data-end=\"262\"\u003e\u003cstrong data-start=\"177\" data-end=\"262\"\u003e\u003cfont style=\"font-size: 18px;\"\u003ePower Factor Controller 12 steps + TCR with 2.9\" Graphical LCD (TENSE) - RGT-12E\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\u003cp data-start=\"264\" data-end=\"618\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe \u003cstrong data-start=\"317\" data-end=\"326\"\u003eTENSE\u003c\/strong\u003e reactive power controller \u003cstrong data-start=\"290\" data-end=\"301\"\u003eRGT-12E\u003c\/strong\u003e is a fully automatic and highly accurate controller designed for optimal control of compensation steps in electrical power systems. Utilizing digital measurement, advanced algorithms, and a graphical LCD, it ensures stable power factor, efficient reactive power management, and protection of compensation equipment.\u003c\/font\u003e\u003c\/p\u003e\u003ch2 data-start=\"625\" data-end=\"658\"\u003e\u003cstrong data-start=\"628\" data-end=\"658\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eKey Features and Functions\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\u003ch3 data-start=\"660\" data-end=\"708\"\u003e\u003cstrong data-start=\"664\" data-end=\"708\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAutomatic Compensation Step Setting\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cp data-start=\"709\" data-end=\"753\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe controller self-configures upon power-up:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"754\" data-end=\"917\"\u003e\n\u003cli data-start=\"754\" data-end=\"823\"\u003e\n\u003cp data-start=\"756\" data-end=\"823\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAutomatically determines the size of connected capacitor steps\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"824\" data-end=\"863\"\u003e\n\u003cp data-start=\"826\" data-end=\"863\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eParameters can also be entered manually\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"864\" data-end=\"917\"\u003e\n\u003cp data-start=\"866\" data-end=\"917\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe system continuously monitors the status of each step\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 data-start=\"919\" data-end=\"954\"\u003e\u003cstrong data-start=\"923\" data-end=\"954\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAdvanced Switching Control\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cp data-start=\"955\" data-end=\"998\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe controller switches steps on and off so that:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"999\" data-end=\"1283\"\u003e\n\u003cli data-start=\"999\" data-end=\"1063\"\u003e\n\u003cp data-start=\"1001\" data-end=\"1063\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ea stable power factor is achieved with a minimum number of switches\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1064\" data-end=\"1112\"\u003e\n\u003cp data-start=\"1066\" data-end=\"1112\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eindividual steps are evenly loaded\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1113\" data-end=\"1178\"\u003e\n\u003cp data-start=\"1115\" data-end=\"1178\"\u003e\u003cfont style=\"font-size: 14px;\"\u003epriority is given to capacitors with the lowest residual charge\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1179\" data-end=\"1283\"\u003e\n\u003cp data-start=\"1181\" data-end=\"1283\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ethe status of each step (faults, power changes, removal, and re-connection) is checked simultaneously\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 data-start=\"1285\" data-end=\"1333\"\u003e\u003cstrong data-start=\"1289\" data-end=\"1333\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTCR (Thyristor Switched Reactor) Support\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cp data-start=\"1334\" data-end=\"1418\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe controller provides the ability to manage compensation with thyristor switched reactors, which is ideal for:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"1419\" data-end=\"1505\"\u003e\n\u003cli data-start=\"1419\" data-end=\"1442\"\u003e\n\u003cp data-start=\"1421\" data-end=\"1442\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIndustrial applications\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1443\" data-end=\"1468\"\u003e\n\u003cp data-start=\"1445\" data-end=\"1468\"\u003e\u003cfont style=\"font-size: 14px;\"\u003edynamic compensation\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1469\" data-end=\"1505\"\u003e\n\u003cp data-start=\"1471\" data-end=\"1505\"\u003e\u003cfont style=\"font-size: 14px;\"\u003esystems with frequently changing loads\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 data-start=\"1507\" data-end=\"1541\"\u003e\u003cstrong data-start=\"1511\" data-end=\"1541\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAdvanced Measurement and Analysis\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cul data-start=\"1542\" data-end=\"1796\"\u003e\n\u003cli data-start=\"1542\" data-end=\"1606\"\u003e\n\u003cp data-start=\"1544\" data-end=\"1606\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMeasurement of harmonic voltages and currents up to the \u003cstrong data-start=\"1586\" data-end=\"1604\"\u003e31st harmonic\u003c\/strong\u003e\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1607\" data-end=\"1654\"\u003e\n\u003cp data-start=\"1609\" data-end=\"1654\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMonitoring of total energy (import and export)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1655\" data-end=\"1695\"\u003e\n\u003cp data-start=\"1657\" data-end=\"1695\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTHD-V and THD-I measurements for each phase\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1696\" data-end=\"1796\"\u003e\n\u003cp data-start=\"1698\" data-end=\"1796\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eGeneration of power analysis (\u003cstrong data-start=\"1721\" data-end=\"1746\"\u003e20 samples of 9999 min each\u003c\/strong\u003e) - very useful for designing compensation units\u003c\/font\u003e\u003cstrong data-start=\"1802\" data-end=\"1845\" style=\"color: rgb(25, 32, 39); font-family: inherit; font-size: 18px;\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eFlexible Connection of Compensation Elements\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp data-start=\"1846\" data-end=\"1864\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eApplication options:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"1865\" data-end=\"1977\"\u003e\n\u003cli data-start=\"1865\" data-end=\"1895\"\u003e\n\u003cp data-start=\"1867\" data-end=\"1895\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSingle-phase capacitors\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1896\" data-end=\"1925\"\u003e\n\u003cp data-start=\"1898\" data-end=\"1925\"\u003e\u003cfont style=\"font-size: 14px;\"\u003etwo-phase capacitors\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1926\" data-end=\"1954\"\u003e\n\u003cp data-start=\"1928\" data-end=\"1954\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ethree-phase capacitors\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1955\" data-end=\"1977\"\u003e\n\u003cp data-start=\"1957\" data-end=\"1977\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eshunt reactors\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 data-start=\"1979\" data-end=\"2013\"\u003e\u003cstrong data-start=\"1983\" data-end=\"2013\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAdjustable Time Functions\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cp data-start=\"2014\" data-end=\"2029\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eCan be set:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"2030\" data-end=\"2143\"\u003e\n\u003cli data-start=\"2030\" data-end=\"2045\"\u003e\n\u003cp data-start=\"2032\" data-end=\"2045\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eintervention time\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2046\" data-end=\"2063\"\u003e\n\u003cp data-start=\"2048\" data-end=\"2063\"\u003e\u003cfont style=\"font-size: 14px;\"\u003edischarge time\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2064\" data-end=\"2143\"\u003e\n\u003cp data-start=\"2066\" data-end=\"2143\"\u003e\u003cfont style=\"font-size: 14px;\"\u003esettling time\u003cbr data-start=\"2080\" data-end=\"2083\"\u003eThis allows for precise adaptation of control to the nature of the operation.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 data-start=\"2145\" data-end=\"2170\"\u003e\u003cstrong data-start=\"2149\" data-end=\"2170\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eGenerator Functions\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cp data-start=\"2171\" data-end=\"2186\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe controller features:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"2187\" data-end=\"2264\"\u003e\n\u003cli data-start=\"2187\" data-end=\"2218\"\u003e\n\u003cp data-start=\"2189\" data-end=\"2218\"\u003e\u003cfont style=\"font-size: 14px;\"\u003egenerator control input\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2219\" data-end=\"2264\"\u003e\n\u003cp data-start=\"2221\" data-end=\"2264\"\u003e\u003cfont style=\"font-size: 14px;\"\u003egenerator power compensation function\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 data-start=\"2271\" data-end=\"2316\"\u003e\u003cstrong data-start=\"2274\" data-end=\"2316\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTechnical Characteristics (brief overview)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\u003cp\u003e\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\u003c\/p\u003e\u003cul data-start=\"2318\" data-end=\"2680\"\u003e\n\u003cli data-start=\"2318\" data-end=\"2356\"\u003e\n\u003cp data-start=\"2320\" data-end=\"2356\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e12 relay compensation outputs\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2357\" data-end=\"2372\"\u003e\n\u003cp data-start=\"2359\" data-end=\"2372\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTCR support\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2373\" data-end=\"2402\"\u003e\n\u003cp data-start=\"2375\" data-end=\"2402\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eGraphical 2.9\" LCD display\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2403\" data-end=\"2433\"\u003e\n\u003cp data-start=\"2405\" data-end=\"2433\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAutomatic step setting\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2434\" data-end=\"2472\"\u003e\n\u003cp data-start=\"2436\" data-end=\"2472\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eHarmonic measurement up to the 31st order\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2473\" data-end=\"2510\"\u003e\n\u003cp data-start=\"2475\" data-end=\"2510\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eEnergy statistics and history\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2511\" data-end=\"2528\"\u003e\n\u003cp data-start=\"2513\" data-end=\"2528\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTHD-V \/ THD-I\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2529\" data-end=\"2589\"\u003e\n\u003cp data-start=\"2531\" data-end=\"2589\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSupport for single-phase, two-phase, and three-phase steps\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2590\" data-end=\"2641\"\u003e\n\u003cp data-start=\"2592\" data-end=\"2641\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProgrammable off, on, and discharge times\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2642\" data-end=\"2680\"\u003e\n\u003cp data-start=\"2644\" data-end=\"2680\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProtection against step faults\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":55794558468431,"sku":"RGT-12E","price":220.48,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/4589\/0127\/files\/a1a8c8ce294759ea0cac4554bed17012.png?v=1756156244"},{"product_id":"rgt-12svc-12-lygiu-reaktyviosios-galios-valdiklis-tcr-su-rs485-modbus-rtu","title":"RGT-12SVC - 12-level reactive power controller +TCR with RS485 ModBus RTU","description":"\u003cp\u003e \u003cstrong\u003e12-step + TCR power factor controller with 2.9-inch graphic LCD display and RS-485 (TENSE)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003eThe RGT-12SVC\u003c\/strong\u003e reactive power controller \u003cstrong\u003e(TENSE\u003c\/strong\u003e ) is a fully automatic device for optimal switching of compensation stages.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e Digital processing of the measured values ​​of the regulator ensures high accuracy in estimating effective voltage, current and power factor.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e \u003cp\u003eThe device is installed fully automatically - the controller itself determines the size of the individual connected compensation stages. These parameters can also be entered directly manually.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e The controller switches the compensation stages on and off so that the reactive power is regulated with as few switching operations as possible. At the same time, the controller takes into account the uniform load of the individual stages and gives priority to those stages that have been disconnected for the longest time and have the minimum residual load. During the regulation process, the compensation stages are constantly monitored in parallel - faults and changes in values ​​are detected, temporarily removed stages are periodically checked and, if necessary, re-included in the regulation process.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003e\u003cp\u003e Generator input and generator compensation\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Acceleration, discharge and settling times can be set\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Remote communication via RS485 (RS485 ModBus RTU)\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Single-phase, two-phase and three-phase capacitor and shunt reactor can be connected\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e \u003cp\u003eHarmonic voltage and current up to the 31st harmonic can be monitored\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Total energy (import and export) can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e THD-V and THD-I values ​​of each phase can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cp\u003e Create power analysis (20 samples 9999 min.) - for capacitor selection\u003c\/p\u003e\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":55794558501199,"sku":"RGT-12(SVC)","price":262.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/4589\/0127\/files\/ae4bcd478955332c8f4396aa87708907.png?v=1756156248"},{"product_id":"12-lygiu-reaktyviosios-galios-valdiklis-su-led-ekranu","title":"12-level reactive power controller with LED display","description":"\u003cp\u003e\u003cstrong\u003e12-step Single-Phase Connection Power Factor Controller for Power Factor Control in Grids with Symmetrical Loads (TENSE)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eReactive Power Control Relay RGM-12S is designed to reduce inductive powers, which are not used by loads but are drawn from the grid. When inductive reactive power is drawn from the grid, it intervenes by switching on capacitors of appropriate value. In this way, it strives to ensure that the Cos phi value reaches the desired level.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003e7 Different power factor compensation programs\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eManual power factor compensation programs\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eCan compensate only inductive systems\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eAutomatic step measurement\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eAdjustable step connection, release, and discharge times\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eAdjustable voltage and current harmonic signal values\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eOver and under compensation alarm values can be set\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eVoltage, harmonic voltage\/current, over and under compensation alarm output\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eVoltage, current and frequency values can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eActive, reactive and apparent power values can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eUp to 15th harmonic THD-I can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eUp to 15th harmonic THD-V can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eCosine value can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003ePower factor value can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eAutomatic fan output\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eEqual aging in steps (in some compensation programs)\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":55794558533967,"sku":"RGM-12S","price":168.84,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/4589\/0127\/files\/0764c9ac7c5fc216c12aa893b22e4e13.webp?v=1756156252"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/4589\/0127\/collections\/8ce163ce9f7b9a56a1e074bbfcc23630.webp?v=1748694963","url":"https:\/\/pelek.lt\/en\/collections\/kompensavimo-komponentai.oembed","provider":"Lietuva Pelek","version":"1.0","type":"link"}